Preliminary Studies for Dosimetric Response of a Synthetic Dye for Gamma Dosimetry
PDF

Keywords

 Aqueous Solutions, Reactive Orange 122, Gamma radiation, ?coloration, Absorbance.

How to Cite

Muhammad Khawar Hayat, Ramiza, Taqmeem Hussain, Abdul Hanan Saeed, Inam ul Haq, & Nasim Akhtar. (2016). Preliminary Studies for Dosimetric Response of a Synthetic Dye for Gamma Dosimetry. Journal of Basic & Applied Sciences, 12, 406–410. https://doi.org/10.6000/1927-5129.2016.12.63

Abstract

Aqueous solutions of Sandalfix Orange C2RL (SO) dye were used to check its feasibility as a new passive dosimeter. UV/VIS spectrophotometer was utilized to determine the absorption peak (λmax) of dye; which was 430 nm. SO followed Beer’s law satisfactorily. The absorbance (A) of the sample solutions was decreased with increase in absorbed dose (D). The %decoloration (%Ð) showed an exponential increase and logarithmic increase within low and high dosimetry range, respectively. The pH sensitivity of the sample solutions at different doses was also observed.

https://doi.org/10.6000/1927-5129.2016.12.63
PDF

References

Nasef BEA, Yun-Dong C, Walker ML, Sheikhly MA, Mclaughlin WL. Anionic triphenylmethane dye solutions for low-dose food irradiation dosimetry. J Radiat Phys Chem 1995; 46: 1189-97. http://dx.doi.org/10.1016/0969-806X(95)00353-Y

Shahid MAK, Kousar N, Akhtar N, Hussain T, Awan MS, Mubashir A, Bashir B, Javed A. Dosimetry Characterization of Unknown Dye Polyvinyl Alcohol Films. J Basic App Sci 2012; 8(2): 508-12. http://dx.doi.org/10.6000/1927-5129.2012.08.02.42

Hussain T, Hussain MY, Toqeer I, Akhtar N, Inam-ul-Haq, Farooq H. Gamma dosimetric response of sandalfix golden yellow CRL dye solutions for gamma dosimetry using Cs137 in the range 0-1kGy. J Basic App Sci 2012; 8(2): 482-84. http://dx.doi.org/10.6000/1927-5129.2012.08.02.38

Hussain T, Hussain MY, Shahbaz M, Inam-ul-Haq, Farooq H, Ali S. Radiolysis of commercial dyes in aqueous solutions to produce dosimeters for gamma dosimetry. J Basic App Sci 2012; 8(2): 315-18. http://dx.doi.org/10.6000/1927-5129.2012.08.02.10

Hussain MY, Shad NA, Akhtar N, Ali S, Hussain T, Inam-ul-Haq. Commercial SFG yellow CRL dye aqueous solutions for gamma dosimetry. Pak J Agri Sci 2009; 46(1): 78-81.

Hussain MY, Islam-ud-Din, Hussain T, Akhtar N, Ali S, Inam-ul-Haq. 2009. Response of sandal fix red C4BLN dye solutions using Co60 ?-Radiation source at intermediate doses. Pak J Agri Sci 2009; 46(3): 224-27.

Hussain T, Shahid MAK, Shahbaz M, Inam-ul-Haq, Farooq H. Gamma radiation effect on commercial reactive dye in the range 0-100kGy using the idea of the de-coloration factor and extinction coefficient. J Basic App Sci 2012; 8(2): 581-84. http://dx.doi.org/10.6000/1927-5129.2012.08.02.51

Hussain T, Shahbaz M, Inam-ul-Haq, Farooq H, Amin N, Jamil Y. Dosimetric characteristics of aqueous solutions of sandalfix red dye for gamma dosimetry. J Basic App Sci 2012; 8(2): 437-43. http://dx.doi.org/10.6000/1927-5129.2012.08.02.30

Akhtar F, Hussain T, Shahbaz M, Inam-ul-Haq, Toqeer I, Farooq H. Usability of aqueous solutions of commercial reactive dye for gamma dosimetry. Acad Res Int 2014; 5(1): 32-36.

Akhtar S, Hussain T, Shahzad A, Hussain MY, Akhtar N. Radiation induced decoloration of reactive dye in PVA films for film dosimetry. J Basic App Sci 2013; 9: 416-19.

Akhtar S, Hussain T, Shahzad A, Qamar-ul-Islam. The feasibility of reactive dye in PVA films as high dosimeter. J Basic App Sci 2013; 9: 420-23.

Antar EM. Effect of ?-ray on optical characteristics of dyed PVA films. J Radiat Res Appl Sci 2014; 7: 129-34. http://dx.doi.org/10.1016/j.jrras.2014.01.002

Batool J, Shahid SA, Ramiza, Akhtar N, Naz A, Yaseen M, Ullah I, Nadeem M, Shakir I. A study on dosimetric characterization of direct Yellow 12 dye at high radiation ?-dose. Bull Korean Chem Soc 2012; 33: 2265-68. http://dx.doi.org/10.5012/bkcs.2012.33.7.2265

Rauf M, Ashraf SS. Radiation induced degradation of dyes—an overview. J Hazard Mater 2009; 166: 6-16. http://dx.doi.org/10.1016/j.jhazmat.2008.11.043

Rahim FA, Eid SA, Souka N, McLaughlin WL. The radiolysis of bromophenol blue in aqueous solutions. Int J Radiat Appl Instrum C Radiat Phys Chem 1986; 27: 211-17.

Ajji Z. Usability of aqueous solutions of methyl red as high-dose dosimeter for gamma radiation. ?Radiat Meas 2006; 41: 438-42. http://dx.doi.org/10.1016/j.radmeas.2005.09.003

Sun W, Chen L, Tian J, Wang J, He S. Degradation of a monoazo dye Alizarin Yellow GG in aqueous solutions by gamma irradiation: Decolorization and biodegradability enhancement. Radiat Phys Chem 2013; 83: 86-89. http://dx.doi.org/10.1016/j.radphyschem.2012.10.014

Bokhari TH, Kashif M, Bhatti IA, Zubair M, Adeel S, Yousaf M, Ahmad M, Iqbal M, Usman M, Zuber M, Mansha A. Degradation study of C.I. Reactive Yellow 145 by advanced oxidation process. Asian J Chem 2013; 25: 8668-72. http://dx.doi.org/10.14233/ajchem.2013.14996

Gafar SM, El-Ahdal MA. Dosimetric characteristics of 2, 6 di-nitro phenol for high dose dosimetry. Dyes Pigm 2014; 109: 67-71. http://dx.doi.org/10.1016/j.dyepig.2014.05.001

Hussain T, Shahbaz M, Inam-ul-Haq, Farooq H. Radiolytic reduction of aqueous solutions of a commercial reactive dye in the range 0-100kGy by Co60 gamma radiation source. J Basic App Sci 2012; 8(2): 280-85. http://dx.doi.org/10.6000/1927-5129.2012.08.02.04

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

Copyright (c) 2016 Muhammad Khawar Hayat, Ramiza, Taqmeem Hussain, Abdul Hanan Saeed, Inam ul Haq , Nasim Akhtar