Determination and Comparison of Aspartame Level in Low Calorie Table Top Sweeteners by Ultraviolet Visible Spectroscopy
PDF

Keywords

Aspartame, UV/Visible spectroscopy, Sweetener, KMnO4.

How to Cite

Narjis Naz, & Subreena Altaf. (2018). Determination and Comparison of Aspartame Level in Low Calorie Table Top Sweeteners by Ultraviolet Visible Spectroscopy. Journal of Basic & Applied Sciences, 14, 197–201. https://doi.org/10.6000/1927-5129.2018.14.30

Abstract

The analysis of aspartame was done in table top sweeteners using Ultraviolet visible Spectroscopy. The method is based on the formation of manganate ion (MnO42-) when potassium permanganate oxidizes aspartame. The analysis was carried out at a fixed wavelength of 600nm exactly after 48 minutes of sample preparation using 1mL of 0.01M KMnO4 and 2mL of 1.0M NaOH. A linear calibration graph was obtained with the regression coefficient of 0.9999 and the percentage recovery was in the range of 92.7-101.6%. The Relative standard deviation for the method was found to be 1.03%.

https://doi.org/10.6000/1927-5129.2018.14.30
PDF

References

Lebedev I, Park J, Yaylaian R. Popular Sweeteners and their Health Effects. BS. Dissertation, Worcester Polytechnic Institute, Massachusetts, United States, 2009; 1.

Gardner C, Gidding S, Steffen LM, Johnsons RK, Reader D. Nonnutritive Sweeteners: Current Use and Health Perspectives. American Heart Association Journal 2012; 126: 509-519.

Nill, Ashley G. The History of Aspartame (2000 Third Year Paper), Harvard University's DASH. (Accessed May 8, 2014 4:44:17 AM EDT).

Aspartame, a Guide to Consumers, Policymakers and the Media, Grocery Manufacturers Association.

Williams S. Neurodegenerative diseases and aspartame. MS. Dissertation 2008.

Gold MD. Independent Analysis of the “Opinion of the European Commission, Scientific Committee on Food: Update on the Safety of Aspartame / E951” Aspartame Toxicity Information Center,12 East Side Dr., Suite 2-17 Concord, New Hampshire, 02139 USA 1-603-225-2110 2003.

Gupta S, Mahajan V, Mahajan S, Tandon VR. Artificial Sweeteners. Journal of Medical Education and Research 2012; 14(1): 2-3.

Verzella G, Bagnasco G, Mangia A. Ion Pair High Performance Liquid Chromatography Analysis of Aspartame and Related Products. Journal of Chromatography 1985; 349: 83-89. https://doi.org/10.1016/S0021-9673(00)90636-8

Gibbs BF, Alli I, Mulligan CN. Simple and rapid high-performance liquid chromatographic method for the determination of aspartame and its metabolites in foods. Journal of Chromatography A 1996; 725: 372-377. https://doi.org/10.1016/0021-9673(95)01068-8

Idris M, Varshney KM, Sudhakar P, Shukla SK, Baggi TR. HPLC determination of Aspartame in Table top Sweeteners by Precolumn Derivatization using 2, 4-Dinitrofluorobenzene. International Journal of Pharmacy and Pharmaceutical Sciences 2012; 4(1): ISSN- 0975-1491.

Ree M, Stoa E. Simultaneous determination of aspartame, benzoic acid, caffeine, and saccharin in sugar-free beverages using High performance liquid chromatography. Concordia College Journal of Analytical Chemistry I: 2011; 73-77.

Sanchez FG, Gallardo AA. Liquid chromatographic and spectrofluorimetric determination of aspartame and glutamate in foodstuffs following fluorescamine fluorigenic labelling. Analytica Chimica Acta 1992; 270: 45-53. https://doi.org/10.1016/0003-2670(92)80090-T

Odaci D, Timur S, Telefoncu A. Carboxyl esterase-alcohol oxidase based biosensor for the aspartame determination. Food Chemistry 2004; 84: 493-496. https://doi.org/10.1016/j.foodchem.2003.07.032