Radiation Induced Decoloration of Reactive Dye in PVA Films for Film Dosimetry
PDF

Keywords

Thin film, polyvinyl alcohol, methyl orange, γ-radiation, decoloration.

How to Cite

Shaheen Akhtar, Taqmeem Hussain, Aamir Shahzad, Qamar-ul-Islam, Muhammad Yousuf Hussain, & Nasim Akhtar. (2021). Radiation Induced Decoloration of Reactive Dye in PVA Films for Film Dosimetry. Journal of Basic & Applied Sciences, 9, 416–419. https://doi.org/10.6000/1927-5129.2013.09.53

Abstract

The investigation of film dosimeters made from polyvinyl alcohol (PVA) films dyed with methyl orange (MO) to enable their use in high dose radiation processing applications was studied. The dosimetric change in these films at pre and post irradiation was studied spectrophotometrically. Radiolytic bleaching was observed in PVA aided films exposed with Cs137 γ-source in dose range of 100-200kGy. The effects of pH, dye concentration and film thickness on the radiation response of the film dosimeters were discussed. The stability of MO-PVA films before and after exposure of radiation was also examined at ambient temperature and was found to be higher for long times at pre and post irradiation stages.

https://doi.org/10.6000/1927-5129.2013.09.53
PDF

References

Kovacs A, Baranyai M, Wojnarovits L, Slezsa I, Mclaughlin WI, Miller A, Moussa A. Dose determination with nitro blue tetrazolium containing radiochromic dye films by measuring absorbed and reflected light. Radiat Phys Chem 2000; 57: 711-16. http://dx.doi.org/10.1016/S0969-806X(99)00501-0

Hussain T, Hussain MY, Shahbaz M, Inam-ul-Haq, Farooq H, Ali S. Radiolysis of commercial dyes in aqueous solutions to produce dosimeters for gamma dosimetry. J Basic App Sci 2012; 8(2): 315-18.

Hussain T, Shahbaz M, Inam-ul-Haq, Farooq H, Amin N, Jamil Y. Dosimetric Characteristics of Aqueous Solutions of Sandalfix Red Dye for Gamma Dosimetry. J Basic App Sci 2012; 8(2): 437-43.

Shahid MAK, Kousar N, Akhtar N, Hussain T, Awan MS, Mubashir A, Bashir B, Javed A. Dosimetry Characterization of Unknown Dye Polyvinyl Alcohol Films. J Basic App Sci 2012; 8(2): 508-12.

Mai HH, Duong ND, Kojima T. Dyed polyvinyl chloride films for use as high-dose routine dosimeters in radiation processing. Radiat Phys Chem 2004; 69: 439-44. http://dx.doi.org/10.1016/j.radphyschem.2003.08.006

Shahzad A, He M-G. Thermal conductivity of complex (dusty) plasmas. Phys Plasmas 2012; 19: 083707. http://dx.doi.org/10.1063/1.4748526

Shahzad A, He M-G. Thermal conductivity of three dimensional Yukawa liquids (dusty plasmas). Contrib Plasma Phy 2012; 52: 665-67. http://dx.doi.org/10.1002/ctpp.201200002

Kattan M, Daher Y, Alkassiri H. A high-dose dosimeter-based polyvinyl chloride dyed with malachite green. Radiat Phys Chem 2007; 76: 1195-99. http://dx.doi.org/10.1016/j.radphyschem.2006.12.004

Bhat NV, Nate MM, Bhat RM, Bhatt BC. Effect of γ-irradiation on polyvinyl alcohol films doped with some dyes and their use in dosimetric studies. Indian J Pure Appl Phys 2007; 45: 545-48.

Mai HH, Solomon HM, Taguchi M, Kojima T. Polyvinyl butyral films containing leuco-malachite green as low-dose dosimeters. Radiat Phys Chem 2008; 77: 457-62. http://dx.doi.org/10.1016/j.radphyschem.2007.06.012

Akhavan A, Sohrabpour M, Sharifzadeh M. Preparation of a new chemical radiochromic film dosimeter. Radiat Phys Chem 2002; 63: 773-75. http://dx.doi.org/10.1016/S0969-806X(01)00610-7

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.