Gamma Dosimetric Response of Sandalfix Golden Yellow CRL Dye Solutions for Gamma Dosimetry Using Cs137 in the Range 0-1KGy
PDF

Keywords

 Sandalfix Golden Yellow CRL, dosimetry, Cs137 gamma source, radiolytic bleaching.

How to Cite

Muhammad Yousuf Hussain, Taqmeem Hussain, Irfan Toqeer, Nasim Akhtar, Inam-ul-Haq, & Hashim Farooq. (2021). Gamma Dosimetric Response of Sandalfix Golden Yellow CRL Dye Solutions for Gamma Dosimetry Using Cs137 in the Range 0-1KGy. Journal of Basic & Applied Sciences, 8(2), 482–484. https://doi.org/10.6000/1927-5129.2012.08.02.38

Abstract

The effect of gamma radiation source (Cs137) on the aqueous solutions of the Sandalfix Golden Yellow CRLdye was determined in the range 0-1kGy. ?max of the dye was determined by UV/VIS spectrophotometer before the exposure of gamma radiations and was found to be 422 nm. Absorbance of the sample solutions was studied at ?max of the dye at pre and post irradiation. It was determined that the Absorbance of the sample solutions was decreased with increasing absorbed dose. The exposed dye solutions were found to be discolored due to the structural changes in the dye solutions and the discoloration of the dye was found linear with respect to absorbed dose.

https://doi.org/10.6000/1927-5129.2012.08.02.38
PDF

References

Nasef BEA, Yun-Dong C, Walker ML, Sheikhly MA, Mclaughlin WL. Anionic triphenylmethane dye solutions for low-dose food irradiation dosimetry. J Radiat Phys Chem 1995; 46: 1189-97. http://dx.doi.org/10.1016/0969-806X(95)00353-Y

Hussain MY, Shad NA, Nasim-Akhtar S. Ali, Hussain T, Inam-ul-Haq. Commercial SFG Yellow CRL dye aqueous solutions for gamma dosimetry. Pak J Agric Sci 2009; 46(1): 78-81.

Hussain MY, Islam-ud-Din, T. Hussain, Nasim-Akhtar, S. Ali, Inam-ul-Haq. Response of Sandalfix Red C4BLN dye solutions using Co60 ?-Radiation source at intermediate doses. Pak J Agri Sci 2009; 46(3): 224-27.

Hussain T, Shahbaz M, Inam-ul-Haq, Farooq H. Radiolytic reduction of aqueous solutions of a commercial reactive dye in the range 0-100kgy by Co60 gamma radiation source. J Basic App Sci 2012; 8(2): 280-85.

Hussain T, Hussain MY, Shahbaz M, Inam-ul-Haq, Farooq H, Ali S. Radiolysis of commercial dyes in aqueous solutions to produce dosimeters for gamma dosimetry. J Basic App Sci 2012; 8(2): 315-18.

Masaaki T, Yoshishige S, Tsuneo S, Noriyuki H, Yasuyuki H, Hiromi S. Gamma-ray response of a clear, crosslinked PMMA dosimeter, Radix W. Radiat Phys Chem 2007; 76: 1619-23. http://dx.doi.org/10.1016/j.radphyschem.2006.02.002

Ahmad AL, Pausa SW. Reactive dyes decolourization from an aqueous solution by combined coagulation/ micellarenhanced ultrafiltration process. Chem Eng J 2007; 132:257-65. http://dx.doi.org/10.1016/j.cej.2007.01.005

Rauf MA, Ashraf SS. Radiation induced degradation of dyes-An overview. J Hazard Mat 2008; HAZMAT-9131: 1-11.

Emi RG, Andras K, Fletcher JJ. Dosimetry characterization of tetrazolium violet-polyvinylalcohol films. Radiat Phys Chem 2007; 76: 1519-22. http://dx.doi.org/10.1016/j.radphyschem.2007.02.064

Khan HM, Anwer M, Chaudhry ZS. Dosimetric characterisation of aqueous solution of brilliant green for low dose food irradiation dosimetry. J Radiat Phys Chem 2002; 63: 713-17. http://dx.doi.org/10.1016/S0969-806X(01)00640-5

Parwate DV, Sarma ID, Batra RJ. Preliminary feasibility study of congo red dye as a secondary dosimeter. Radiat Meas doi:10.1016/j.radmeas.2007;03.002.